# Passive cell-balancing estimate # Scope: Resistive cell bleed balancing with constant voltage/current approximation. # Status: illustrative worked example; engineering review pending. # Inputs are example values. Checks are editable example requirements, not standards. cellVoltage = 4.2 V resistor = 100 ohm imbalance = 0.1 Ah current := cellVoltage/resistor [A] power := cellVoltage^2/resistor [W] duration := imbalance/current [h] check resistor power budget: power <= 0.25 W scenario alternative: cellVoltage = 3.36 V