# Zener shunt-regulator screening # Scope: Shunt regulator at supplied zener voltage; ideal clamp. # Status: illustrative worked example; engineering review pending. # Inputs are example values. Checks are editable example requirements, not standards. supply = 12 V zener = 5.1 V seriesResistance = 330 ohm load = 10 mA seriesCurrent := (supply-zener)/seriesResistance [A] zenerCurrent := seriesCurrent-load [A] zenerPower := zener*zenerCurrent [W] check regulation current positive: zenerCurrent > 0 A scenario alternative: supply = 9.6 V