# Gasket seating and joint compression # Scope: Average gasket seating pressure from net clamp load. # Status: illustrative worked example; engineering review pending. # Inputs are example values. Checks are editable example requirements, not standards. preload = 10000 N openingForce = 2000 N area = 1000 mm^2 pressure := (preload-openingForce)/area [MPa] check seating target: pressure >= 5 MPa scenario alternative: preload = 8000 N