# Riveted-joint load screening # Scope: Equal shear sharing among single-shear solid rivets. # Status: illustrative worked example; engineering review pending. # Inputs are example values. Checks are editable example requirements, not standards. force = 1000 N count = 4 diameter = 4 mm stress := force/(count*pi*diameter^2/4) [MPa] check rivet shear budget: stress <= 60 MPa scenario alternative: force = 800 N