# Long-solenoid field estimate # Scope: Long air-core solenoid approximation; fringing omitted. # Status: illustrative worked example; engineering review pending. # Inputs are example values. Checks are editable example requirements, not standards. turns = 500 current = 1 A length = 100 mm permeability = 0.0000012566370614 H/m field := permeability*turns*current/length [T] check field target: field >= 0.005 T scenario alternative: turns = 400