# Light-pipe acceptance screening # Scope: Straight light-pipe transmission using supplied coupling and loss-per-length; bends omitted. # Status: illustrative worked example; engineering review pending. # Inputs are example values. Checks are editable example requirements, not standards. inputPower = 10 mW coupling = 0.8 attenuation = 0.2 m^-1 length = 1 m outputPower := inputPower*coupling*exp(-attenuation*length) [mW] check output power target: outputPower >= 5 mW scenario alternative: inputPower = 8 mW