# Cylinder speed and flow # Scope: Incompressible flow/piston area speed; pneumatic flow must use cylinder conditions. # Status: illustrative worked example; engineering review pending. # Inputs are example values. Checks are editable example requirements, not standards. flow = 5 L/min diameter = 32 mm area := pi*diameter^2/4 [mm^2] speed := flow/area [mm/s] check speed budget: speed <= 150 mm/s scenario alternative: flow = 4 L/min