# Pump affinity-law scaling # Scope: Speed affinity at unchanged impeller and fluid; similarity assumed. # Status: illustrative worked example; engineering review pending. # Inputs are example values. Checks are editable example requirements, not standards. speedRatio = 1.2 flow = 10 L/min head = 10 m power = 100 W newFlow := flow*speedRatio [L/min] newHead := head*speedRatio^2 [m] newPower := power*speedRatio^3 [W] check motor power budget: newPower <= 200 W scenario alternative: speedRatio = 0.96