# Screw buckling load # Scope: Euler pin-ended solid circular screw column. # Status: illustrative worked example; engineering review pending. # Inputs are example values. Checks are editable example requirements, not standards. diameter = 12 mm length = 0.5 m modulus = 200 GPa load = 1000 N inertia := pi*diameter^4/64 [mm^4] critical := pi^2*modulus*inertia/length^2 [N] factor := critical/load check buckling factor target: factor >= 2 scenario alternative: diameter = 9.6 mm