# Coupling torque and misalignment sizing # Scope: Coupling torque demand using a supplied service factor. # Status: illustrative worked example; engineering review pending. # Inputs are example values. Checks are editable example requirements, not standards. power = 500 W speed = 1500 rpm serviceFactor = 1.5 nominal := power/speed [N*m] designTorque := nominal*serviceFactor [N*m] check coupling rating example: designTorque <= 10 N*m scenario alternative: power = 400 W