# FFT resolution and record length # Scope: Uniform sampled FFT frequency-bin spacing; no spectral interpolation. # Status: illustrative worked example; engineering review pending. # Inputs are example values. Checks are editable example requirements, not standards. sampleRate = 1000 Hz samples = 1024 binWidth := sampleRate/samples [Hz] recordLength := samples/sampleRate [s] check frequency resolution budget: binWidth <= 1 Hz scenario alternative: sampleRate = 800 Hz