# Melting and latent-heat storage # Scope: Sensible heating plus latent heat at fixed properties; losses omitted. # Status: illustrative worked example; engineering review pending. # Inputs are example values. Checks are editable example requirements, not standards. mass = 0.5 kg heatCapacity = 4200 J/(kg*K) rise = 20 K latent = 334000 J/kg power = 500 W energy := mass*(heatCapacity*rise+latent) [J] duration := energy/power [s] check process time budget: duration <= 600.0 s scenario alternative: mass = 0.4 kg